Get Data Today

Who you choose to vet your products makes all the difference.

Our Services

  • Accelerated Ultraviolet  (Accelerated UV)

  • Accelerated Aging
    UL1703 Clause 34; ULC/ORD C1703 Clause 5.16; UL 3703, Clause 60

  • Accessibility
    IEC 61730 MST 11; UL1703 Clause 15; ULC/ORD C1703 Clause 4.10; UL 61730 MST 11

  • Arcing
    UL1703 Clause 40; ULC/ORD C1703 Clause 5.22

  • Bifacial Characterization

  • Bonding Strap Pull Test
    UL2703 Clause 23; UL 3703, Clause 62

  • Bonding Conductor Test
    UL 3703, Clause 22 (Part A), UL 2703, Clause 45 (Part A)

  • Bonding Path Resistance
    UL1703 Clause 25; UL2703 Clause 13; ULC/ORD C1703 Clause 5.8;UL 3703, Clause 42

  • Bypass Diode Functionality
    IEC 61215-2 MQT 18.2; IEC 61730 MST 07; UL 61730 MST 07

  • Bypass Diode Thermal
    IEC 61730 MST 25; IEC 61215 Clause 10.18; IEC 61646 Clause 10.18; IEC 62108 Clause 10.11; IEC 61215 MQT 18.1; UL 61730 MST 25; UL 61215-2 MQT 18.1; IEC 63126 MQT 18 and MST 25; IEC 63163 MQT 18

  • Capacitor Voltage Determination Test
    UL 3703, Clause 51

  • CEC Testing
    California Energy Commission Testing

  • Cold Conditioning
    IEC 61730 MST 55; UL 61730 MST 55

  • Compression Test
    UL 3703, Clause 48; UL 9703 Clause 29; UL 3730 Clause 32

  • Conduit Building
    IEC 61730 MST 33

  • Current Overload Test
    UL 9703 Clause 30

  • Cut Susceptibility
    IEC 61730 MST 12; UL1703 Clause 24; ULC/ORD C1703 Clause 5.7; UL 61730 MST 12

  • Damp Heat
    IEC 61215 Clause 10.13 (1000 hr); IEC 61646 Clause 10.13 (1000 hr); IEC 61730 MST 53 (1000 hr); IEC 62108 Clause 10.7; IEC 61215 MQT 13; UL 61730 MST 53 UL 61215-2 MQT 13; IEC 63163 MQT 13

  • Determination of Cell Temperature Using OC Voltage
    IEC 60904-5

  • Dielectric Voltage Withstand
    IEC 61730 MST 16; UL1703 Clause 26; ULC/ORD C1703 Clause 5.9; UL 3703, Clause 40; UL 9703 Clause 19; UL 3730 Clause 22; UL 6703 Clause 26

  • Dry Heat Conditioning
    IEC 61730 MST 56; UL 61730 MST 56; IEC 63126 MST 56

  • Dynamic Mechanical Load
    IEC 62782 Clause 6

  • Emergency Stop Test
    UL 3703, Clause 55

  • Enclosure Mounting Static Load Test
    UL 3703, Clause 47

  • Energy Storage Solution Testing (ESS Testing)

  • Field Services

  • Final Stabilization
    IEC 61215 MQT 19.2; IEC 63209 Clause 5.11

  • Flexing Test
    UL 3703, Clause 52

  • Golden Module Testing 

  • Ground Continuity
    IEC 61730 MST 13; IEC 62108 Clause 10.3; UL 61730 MST 13

  • Grounding Impedance
    UL 9703 Clause 27; UL 3730 Clause 30

  • Hail Impact
    IEC 61215 Clause 10.17; IEC 61646 Clause 10.17; IEC 62108 Clause 10.9; ANSI/FM 4478 Appendix E (class 4 only); IEC 61215 MQT 17; UL 61215-2 MQT 17; UL 7103 Clause 24; IEC 63163 MQT 17

  • Hail Durability Test (HDT)

  • Hot Spot Endurance
    IEC 61215 Clause 10.9; IEC 61646 Clause 10.9; IEC 61730 MST 22; IEC 62108 Clause 10.17; UL1703 Clause 39; ULC/ORD C1703 Clause 5.21; IEC 61215 MQT 09; UL 61730 MST 22; UL 61215-2 MQT 09; IEC 63126 MQT 09 and MST 22; IEC 63163 MQT 09

  • Humidity / Humidity Freeze
    IEC 61215 Clause 10.12; IEC 61646 Clause 10.12; IEC 61730 MST 52; IEC 62108 Clause 10.8; UL1703 Clause 36; UL2703 Clause 18; ULC/ORD C1703 Clause 5.18; IEC 61215 MQT 12; UL 61730 MST 01; UL 61215-2 MQT 12; IEC 63163 MQT 12; UL 9703 Clause 36; UL 3730 Clause 39; UL 6703 Clause 36; IEC 62938 Clause 6.5

  • Ignitibility
    IEC 61730 MST 24; UL 61730 MST 24

  • Impact
    UL1703 Clause 30; ULC/ORD C1703 Clause 5.13; UL 9703 Clause 25; UL 3730 Clause 28; UL 6703 Clause 30

  • Impulse Voltage
    IEC 61730 MST 14; UL 61730 MST 14

  • Initial Stabilization
    IEC 61215 MQT 19.1; IEC 63209 Clause 5.4

  • Insulation
    IEC 61215 Clause 10.3; IEC 61646 Clause 10.3; IEC 62108 Clause 10.4; IEC 61215 MQT 03; IEC 61730 MST 16; UL 61730 MST 16; UL 61215-2 MQT 03; IEC 63163 MQT 03; IEC 62938 Clause 6.3; IEC 63209 Clause 5.6

  • Insulation Thickness
    IEC 61730 MST 04; UL 61730 MST 04; IEC 63209 Clause 5.9

  • Inverter Testing

  • Lap Shear
    IEC 61730 MST 36; UL 61730 MST 36

  • Leakage Current
    UL1703 Clause 21; ULC/ORD C1703 Clause 5.4; UL 9703 Clause 20; UL 3730 Clause 23; UL 6703 Clause 21

  • Light & Elevated Temperature Induced Degradation (LeTID)

  • Light & Elevated Temperature Induced Degradation (LID)

  • Light Soaking
    IEC 61646 Clause 10.19

  • Marking
    UL1703 Clause 47; ULC/ORD C1703 Clause 7.0; IEC 61730 MST 05; UL 61730 MST 05

  • Materials Creep
    IEC 61730 MST 37; UL 61730 MST 37; IEC 63126 Clause MST 37

  • Maximum Power Determination
    IEC 61215 Clause 10.2; IEC 61646 Clause 10.2; IEC 61215 MQT 02; IEC 61730 MST 03; UL 61730 MST 03; UL 61215-2 MQT 02; IEC 63163 MQT 02; IEC 62938 Clause 6.2

  • Maximum-Voltage Measurements
    UL 3703, Clause 38

  • Measurement of Incident Angle Effects
    IEC 61853-2 Clause 6

  • Measurement of Temperature Coefficients
    IEC 61215 Clause 10.4; IEC 61646 Clause 10.4; IEC 61215 MQT 04; IEC 61853-2 Clause 8

  • Mechanical Load Test
    IEC 61215 Clause 10.16; IEC 61646 Clause 10.16; IEC 61730 MST 34; IEC 62108 Clause 10.13; UL1703 Clause 41; UL2703 Clause 21; ULC/ORD C1703 Clause 5.23; 2 UL 3703, Clause 59; IEC 61215 MQT 16; UL 61730 MST 34; UL 61215-2 MQT 16; UL 7103 Clause 31; IEC 63163 MQT 16

  • Module Breakage
    IEC 61730 MST 32; UL 61730 MST 32

  • Mold Stress-Relief Distortion
    UL 9703 Clause 21; UL 3730 Clause 24; UL 6703 Clause 29

  • Non-uniform Snow Load Test
    IEC 62938 Clause 6.7

  • Off-Axis Beam Damage
    IEC 62108 Clause 10.14

  • Outdoor Exposure
    IEC 61215 Clause 10.8; IEC 61646 Clause 10.8; IEC 62108 Clause 10.16; IEC 61215 MQT 08; UL 61215-2 MQT 08; IEC 63163 MQT 08; IEC 63163 MQT 08

  • Overload Test
    UL 3703, Clause 41

  • PAN File - IAM (Incident Angle Modifier)

  • Partial Discharge
    IEC 61730-2 (2004) MST 15

  • Peel Testing (Non-PV Specific)

  • Performance
    IEC 63209 Clause 5.5

  • Performance at STC and NOCT
    IEC 61215 Clause 10.6; IEC 61646 Clause 10.6 IEC 61215 MQT 06.1 and MQT 06.2; IEC 61730 MST 02; UL 61730 MST 02; UL 61215-2 MQT 06.1

  • Photovoltaic (PV) Module Performance and Energy Rating
    IEC 61853-1

  • Potential Induced Degradation (PID)
    IEC 62804, IEC 62804-1-1

  • Power Restoration Test
    UL 3703, Clause 53

  • Preconditioning
    IEC 61215 Clause 5; IEC 62108 Clause 6

  • Periodic Reliability Test (PRT)

  • PV Module Index Report (PVMI Report)

  • Locked Platform Test
    UL 3703, Clause 54

  • Mechanical Load Test

    • Balanced Load Testing

    • Unbalanced Load Testing

    • Extreme Load Testing

    • High DML

  • Outdoor Exposure
    IEC 61215 Clause 10.8; IEC 61646 Clause 10.8; IEC 62108 Clause 10.16; IEC 61215 MQT 08; UL 61215-2 MQT 08; IEC 63163 MQT 08; IEC 63163 MQT 08

  • Overcurrent Protection Calibration Test
    UL 3703, Clause 50

  • Peel Test
    IEC 61730 MST 35; UL 61730 MST 35

  • Pre-Thermal Cycle
    IEC 62108 Clause 10.8.3

  • Push Test
    UL1703 Clause 23; ULC/ORD C1703 Clause 5.6; UL 9703 Clause 24; UL 3730 Clause 27

  • Rain and Sprinkler Tests
    UL 3703, Clause 49

  • Rating
    UL1703 Clause 46; ULC/ORD C1703 Clause 6.0

  • Reduced Spacings on Printed Wiring Boards Tests
    UL 3703, Clause 44

  • Reverse Current Overload
    IEC 61730 MST 26; UL1703 Clause 28; ULC/ORD C1703 Clause 5.11; UL 61730 MST 26

  • Retention on Junction Box
    IEC 61215 MQT 14.1; UL 61215-2 MQT 14.1

  • Robustness of Terminations
    IEC 61215 Clause 10.14; IEC 61646 Clause 10.14; IEC 61730 MST 42; IEC 62108 Clause 10.12; UL 61730 MST 42; IEC 63163 MQT 14

  • Salt Spray & Ammonia
    IEC 61730 MST 06; UL 61730 MST 06

  • Salt Fog
    IEC 61701; IEC 60068-2-2-52; UL2703 Clause 19.1; UL 7103 Clause 28; UL 3730 Clause 34.1

  • Screw Connections
    IEC 61730 MST 33; UL 61730 MST 33

  • Sharp Edge
    IEC 61730 MST 06; UL 61730 MST 06

  • Static & Dynamic Mechanical Load (SDML)

  • Stability Test
    UL 3703, Clause 46

  • Stabilization
    IEC 63163 MQT 19

  • Strain Relief
    UL1703 Clause 22; ULC/ORD C1703 Clause 5.5; UL 3703, Clause 43; UL 9703 Clause 22; UL 3730 Clause 25; UL 6703 Clause 22

  • Temperature Cycling
    UL1703 Clause 35; UL2703 Clause 17; ULC/ORD C1703 Clause 5.17; UL 9703 Clause 35; UL 3730 Clause 38; UL 6703 Clause 35

  • Temperature Cycling Test for Components Not Within an Enclosure
    UL 3703, Clause 57

  • Humidity Cycling Test for Components Not Within an Enclosure
    UL 3703, Clause 58

  • Thermal Cycling
    IEC 61215 Clause 10.11; IEC 61646 Clause 10.11; IEC 61730 MST 51; IEC 62108 Clause 10.6; IEC 61215 MQT 11; UL 61730 MST 51; UL 61215-2 MQT 11; IEC 63126 MQT 11 and MST 51; IEC 63163 MQT 11; IEC 63209 Clause 5.10

  • Temperature and Irradiance Corrections
    IEC 60891

  • Temperature Test
    IEC 61730 MST 21; UL1703 Clause 19; ULC/ORD C1703 Clause 5.2; UL 3703, Clause 39; UL 61730 MST 21; UL 9703 Clause 18; UL 3730 Clause 21

  • Terminal Box Knock Out
    IEC 61730 MST 44

  • Terminal Torque
    UL1703 Clause 29; UL2703 Clause 14; ULC/ORD C1703 Clause 5.12; UL 3703, Clause 60; IEC 61215 MQT 14.3; UL 9703 Clause 26; UL 3730 Clause 29

  • Test of Cord Anchorage
    IEC 61215 MQT 14.2

  • Thresher Test

  • UV Preconditioning / Conditioning
    IEC 61215 Clause 10.10; IEC 61646 Clause 10.10; IEC 61730 MST 54; IEC 62108 Clause 10.15; IEC 61215 MQT 10; IEC 61730 MST 54.1; UL 61730 MST 54 and MST 54.1; UL 61215-2 MQT 10; IEC 63126 MQT 10 and MST 54; IEC 63163 MQT 10

  • Visual Inspection
    IEC 61215 Clause 10.1; IEC 61646 Clause 10.1; IEC 61730 MST 01; IEC 62108 Clause 10.1; IEC 61215 MQT 01; UL 61730 MST 01; UL 61215-2 MQT 01; IEC 63163 MQT 01; IEC 62938 Clause 6.1; IEC 63209 Clause 5.3

  • Voltage, Current, and Power Measurements
    IEC 62108 Clause 10.2; UL1703 Clause 20; ULC/ORD C1703 Clause 5.3

  • Water Spray
    IEC 62108 Clause 10.10; UL1703 Clause 33; ULC/ORD C1703 Clause 5.15; UL 9703 Clause 33; UL 3730 Clause 36; UL 6703 Clause 33

  • Wet Insulation Resistance
    IEC 62108 Clause 10.5; UL1703 Clause 27; ULC/ORD C1703 Clause 5.10; UL 9703 Clause 34; UL 3730 Clause 37; UL 6703 Clause 27

  • Wet Leakage Current
    IEC 61215 Clause 10.15; IEC 61646 Clause 10.15; IEC 61730 MST 17; IEC 61215 MQT 15; UL 61730 MST 17; UL 61215-2 MQT 15; IEC 63163 MQT 15; IEC 62938 Clause 6.4; IEC 63209 Clause 5.7

  • Wiring Compartment Securement
    UL1703 Clause 42; ULC/ORD C1703 Clause 5.24

Elevate Your Product with the RETC Mark.
Stand out in a competitive market by earning the RETC™ mark—a symbol of technical excellence and global credibility. RETC’s rigorous testing and certification process not only validates your product's quality and performance, it builds trust with buyers, financiers, and developers across the solar industry. When your innovation deserves recognition, RETC certification proves it’s built to perform.